Critical alerts

Critical alerts are generated for events that signal that the server is no
longer functioning.

Table 18. Critical remote alerts

Alphanumeric
pager code

Event

Action

00

Temperature irregularity Generates an alert if any of the monitored temperatures are outside

critical threshold values. Select Temperature Tables in the Temperature,
Voltage and Fan window to view the threshold values. If a critical
temperature condition is detected, the server automatically shuts down
and turns off.

01

Voltage irregularity

Generates an alert if the voltages of any of the monitored power supplies
fall outside their specified operational ranges. Select Voltage Tables in
the Temperature, Voltage and Fan window to view the threshold values.
If a critical voltage condition is detected, the server automatically shuts
down and turns off.

02

Tampering

Generates an alert if physical intrusion of the server box is detected.
Tamper monitoring is not available on some servers, in which case this
setting is ignored.

03

Multiple fan failure

Generates an alert if two or more of the cooling fans in the server fail.

04

Power failure

Generates an alert if any of the server power supplies fail.

05

Hard disk drive failure

Generates an alert if one or more of the hard disk drives in the server
fail.

06

VRM failure

Generates an alert if one or more voltage regulator modules (VRMs) fail.
VRMs are not used on some servers, in which case this setting is
ignored.

07-09

Reserved for future use.

Warning alerts

Warning alerts are generated for events that might progress to a
critical/error level.

Table 19. Warning remote alerts

Alphanumeric
pager code

Event

Action

10

Redundant power
supply failure

Generates an alert if a redundant power supply fails.

11

Single fan failure

Generates an alert if one fan fails.

12

Temperature irregularity Generates an alert if any monitored temperatures are outside the

warning threshold values. Select Temperature Tables in the
Temperature, Voltage and Fan window to view the threshold values.
Unlike the critical temperature event, this event will not initiate system
shutdown.

13

Voltage irregularity

Generates an alert if any monitored voltages are outside the warning
threshold values. Select Voltage Tables in the Temperature, Voltage and
Fan window to view the threshold values. Unlike the critical voltage
event, this event will not initiate an automatic system shutdown.

14 - 19

Reserved for future use.

Note: Hard disk drive Predictive Failure Analysis (PFA) alerts are not

monitored.