IBM Partner Pavilion Remote Supervisor Adapter User Manual

Page 98

Advertising
background image

1. Log in to the Remote Supervisor Adapter. For more information, see

“Accessing the text-based interface through a Telnet connection” on page 65 or
“Accessing the text-based interface through a direct serial connection” on
page 66.

2. In the Advanced System Management window, select Settings. The Settings

window opens.

3. In the Settings window, select System and enter your system contact and

system location information. For information about the system settings, see
“Setting system information” on page 69.

If these fields are already configured, return to the Settings window and
continue with the next step.

4. In the Settings window, select Network Interfaces/Protocols.

5. In the Network Interfaces/Protocols window, select SNMP. The SNMP window

opens.

6. Select Enabled in the SNMP Agent and SNMP Traps fields to forward alerts

to SNMP communities on your network. To enable the SNMP agent, the
following criteria must be met:

v

System contact and system location information must be specified in the
System window.

v

At least one community name must be specified.

v

At least one valid IP address or host name (if DNS is enabled) must be
specified for that community.

Note: Alert recipients whose notification method is SNMP do not receive alerts

unless both the SNMP Agent and SNMP Traps fields are set to
Enabled.

92

Remote Supervisor Adapter: User’s Guide