6. Press F3 and select System Remote Alerts.

System alerts

System alerts are generated for events that occur as a result of system
errors.

Table 20. System remote alerts

Alphanumeric
pager code

Event

Action

20

POST timeout

Generates an alert if an enabled POST timeout value is exceeded. The
POST timeout value is configured in the Server Timeouts section in the
System window.

21

O/S timeout

Generates an alert if an enabled operating system timeout value is
exceeded. The operating system timeout value is configured in the
Server Timeouts section in the System window. This O/S timeout field
must be set to Enabled for remote blue screen capture.

22

Test alert

Generates an alert if Generate Test Alert is clicked on the Remote Alert
Recipients page.

23

Power off

Generates an alert if the server is turned off.

24

Power on

Generates an alert if the server is turned on.

25

Boot failure

Generates an alert if an error occurs that prevents the server from
starting.

26

Loader timeout

Generates an alert if an enabled system loader timeout value is
exceeded. The system loader timeout value is configured in the Server
Timeouts section in the System window.

27

PFA notification

Generates an alert if a PFA notification is generated by the server
hardware. This feature is available only on servers that have
PFA-enabled hardware.

28 - 29

Reserved for future use.

7. Press F3 and select Events For Local Notification.

8. Select the events that you want to store in the event log. The Remote

Supervisor Adapter stores the notification only in the event log.

Local events

Local events are generated for events sent to IBM Director, if it is
installed, on the server where the ASM subsystem resides. These
events are not sent to remote alert recipients.

Table 21. Local events

Event

Action

Temperature

Generates a local notification if any of the monitored temperatures exceeds their
thresholds.

Voltage

Generates a local notification if any of the monitored voltages exceeds their threshold.

Redundant power supply

Generates a local notification if the redundant power supply fails.

Power off

Generates a local notification if the server is turned off.

Remote login

Generates a local notification if a remote login occurs.

System tamper

Generates a local notification if the server covers are removed. This feature is not
available on all servers.

Event log 75% full

Generates a local notification if the event log reaches 75% of capacity.

Event log full

Generates a local notification if the event log is full. When the event log is full, the
oldest events are deleted.

Chapter 7. Configuring your Remote Supervisor Adapter using a text-based interface

83

Advertising