For the Installer

Page

14


Final Check List

Roof Holes Sealed?

Condenser Leveled?

___1. Is the ice system installed indoors in

a location where air and water
temperatures are controlled, and
where they do not exceed the
design limitations?

___2. Is there an electrical service within

sight of the installed machine? Has
the voltage been checked, and
compared to nameplate
requirements?

___3. Have all the plumbing connections

been made and checked for leaks?

Remote condenser
secured?

Machine Leveled?

___4. Has the machine and bin been

leveled?

___5. Is there a minimum of 6 inches

clearance at the rear, left and right
of the machine for proper service
access?

___6. Is the water pressure a minimum of

20 psig?

___7. Has the machine been secured to

the bin or dispenser?

___8. Is there a water shut off valve

installed near the machine?

Plumbing?

___9. Is the remote condenser installed

per local codes, and in a place
where it has adequate ventilation
and minimal solar heat gain?

___10. Has all shipping material and

literature (inside front panel) been
removed from the units?

___11.Have the remote condenser and

pre-charged lines been properly
installed?

Power Supply?

___12. Has the electrical connection between the ice maker and condenser been made?

___13. Verify that the master switch is in the OFF position.

___14. Switch ON the electrical power.

___15. Refer to the Pre-Start instructions, Page 15