Ice-O-Matic GEM0956R User Manual

Page 33

Advertising
background image

GEM0650/0956/1256 Remote

Bearing

Maintenance

Page

27

Bearing Maintenance:
The bearing in the breaker should also be checked at least two (2) times per year.
Switch the machine OFF and check the bearing.


1. Remove the chute cover.













2. Unscrew the ice sweep








3. Removing the water shed and

unscrewing the breaker cover.

Note: Left Hand Threads

5. Inspect the bearing. There should

be plenty of grease in sight. If
grease is needed the bearing and
breaker should be removed to check
the action of the bearing.
It should rotate freely.


6. To remove the breaker, remove the

lower ice chute then take out all
four (4) Allen head cap screws and
pull the breaker off the auger and
evaporator.


7. If the bearing only needs grease,

inject grease into the bearing using
a grease needle.

4

.

Unscrewing the auger stud

See Removal and Replacement Section to replace bearings and seals.

Advertising
This manual is related to the following products: