To Replace the Evaporator:
(Assuming all steps for removal of the thrust bearing, breaker, auger and water seal have been performed).

1. Recover the refrigerant from the ice

machine.

2. Unsweat the refrigerant connections:
a. At the thermostatic expansion valve

outlet.

Evaporator

Auger

Ice Chute

Ice Sweep

b. At the suction line at the joint about

three (3) inches from the
evaporator.

3. Remove the evaporator.
4. Unsweat the drier from the liquid line.
5. After installing a new water seal in the

new evaporator (see “to Replace the
Water Seal) sweat in the new
evaporator at the old tubing
connections.

6. Install a new drier in the liquid line.
7. Evacuate the system until dehydrated,

then weigh in the nameplate charge.
Check for leaks.

8. Install auger, breaker, breaker bearing

assembly and ice discharge chute in
reverse order of disassembly.



To Reassemble the Evaporator and
Auger:
1. After the gear motor has been

inspected, fasten the evaporator to
the gear motor. Torque the bolts to
110 inch pounds

2. Lower the auger into the evaporator

barrel, slightly turning it to match up
with the drive end. Do Not Drop the
auger into the evaporator.

3. Complete the reassembly by reversing

the disassembly for the breaker and
thrust bearing.

Breaker/Divider








Caution: Heat sink the TXV body when unsweating
or resweating the adjacent tubing.