24


Typical Low Side Pressure:
Remote:

34-38

PSIG


Typical Discharge Pressure:
Remote:

220-275

PSIG


Typical Compressor Amp Draw:
GEM0650

115/60/1

8-9

Amps

GEM0956

208-230/60/1

4-5

Amps

GEM1256

208-230/60/1

5-6

Amps


Typical Auger Drive Motor Amp Draw:
GEM0650

115/60/1

3.1

to

3.5

Amps

GEM0956 208-230/60/1

1.6 to 1.8 Amps

GEM1256 208-230/60/1

1.6 to 1.8 Amps


Expansion Valve Superheat:

6-8 degrees


High Pressure Cut Out- Automatic Reset:

450 PSIG


Pump Down Cut Out- Automatic Reset:

15 PSIG


Refrigerant Charge: R404A

GEM0650

Remote

208

ounces

GEM0956

Remote

208

ounces


GEM1256

Remote

208

ounces