Ice-O-Matic GEM0956R User Manual

Page 36

Advertising
background image

GEM0650/0956/1256 Remote

Service Diagnosis

Page

30

Symptom

Possible

Cause

Probable

Correction

No ice is made nothing operates.

•Unit off due to no power

•Restore Power


•Unit off due to master switch in OFF

•Switch master Switch to ON

position


•Unit off due to low water level

•Check water supply, filter

strainer, float valve. Correct

water

supply.


•Unit off due to ice level sensors.

•Check/clean ice level sensors.

(Photo Eyes ) blocked.


•Unit off due to scale on water level

•Clean water level sensor.

sensor.


•Unit off due to high pressure control open.

•Check for water interruption

(water

cooled)

of

fan

motor

failure.


•Auger motor hums but does not turn.

•Auger can’t turn. Circuit board

has

not

yet

shut

it

down.

•Unit is shut down.

•Circuit board has shut ice

machine down due to high

auger

motor

amp

draw.

Check

for

cause

of

high

amp

draw,

including bearings, gear motor

condition

and

scale

on

auger

and

in

evaporator.


•Low

pressure

control

open.

•Auger

not

turning

due

to:

motor

failure;

auger

relay

failure on circuit board; or

or

gears

stripped.

Check

drive train.


•TXV restricted or not metering.

Check bulb temperature.

•Lack

of

refrigerant,

check

for

leak.


•Check for a restricted system.


•No

power

to

circuit

board.

•Check

harness

•Hi or low pressure cut outs

open.


•Circuit

board

gear

motor

relay

will

•Check/replace

board.

not

close.



No ice, auger motor is turning.

•Compressor contactor coil is open.

•Check/replace contactor.


•Compressor

will

not

start.

•Check

start

capacitor.

•Check start relay.

•Check compressor windings.



Advertising