Repositioning the Joystick

NOTE: For this procedure, refer to FIGURE 9.2.
NOTE: Before starting this procedure, it may be necessary to snip the tie-wraps (not shown in

FIGURE 9.2) securing the joystick control cord to the wheelchair. Before snipping the tie-wraps,

note the way the cord is secured to the chair so that it can be re-secured in the same way at the end

of the procedure.
1. Turn the adjustment lock lever to release the joystick mounting tube from the

mounting bracket.

2. Remove the joystick from the wheelchair.
3. Remove the three hex screws that secure both halves of the mounting bracket to the

arm tube.

4. Reposition mounting bracket on opposite arm tube ensuring the threaded plate of the

mounting bracket is on the inside of the arm tube.

5. Using the three hex mounting screws and washers, secure both halves of the mounting

bracket to the arm tube.

6. Slide the joystick mounting tube through the mounting bracket to the desired

position.

7. Turn the adjustment lock lever to secure the joystick mounting tube into the mounting

bracket.

8. If the tie-wraps securing the joystick control cord to the wheelchair were snipped at

the beginning of this procedure, re-secure the cord to the wheelchair with new

tie-wraps in such a way that the control cord will not be pinched or cut during

operation of the wheelchair.

FIGURE 9.2 Repositioning the Joystick

Hex Mounting

Screws

Washers

Mounting

Bracket

Joystick

Mounting

Tube

Arm Tube

Mounting Bracket

(Threaded Plate)

Joystick

Adjustment

Lock Lever

Advertising