Replacing battery box retaining strap, Of figure 11.7, Replacing battery box retaining strap ƽ warning – Invacare Wheelchair XP6500 User Manual

Page 54: Ƽ warning

Advertising
background image

54

Part No. 1123839

SECTION 11—BATTERIES

FIGURE 11.7 Connecting Battery Cables

Replacing Battery Box Retaining Strap

ƽ WARNING

The battery box retaining strap MUST be fastened securely and adjusted properly

to hold battery boxes in place before using the wheelchair.

NOTE: For this procedure, refer to FIGURE 11.8 on page 55.
1. Remove the battery boxes from the wheelchair. Refer to Removing/Installing the

Battery Boxes on page 49.

2. Remove the battery tray from the wheelchair. Refer to Installing/Removing Battery

Tray on page 50.

ƽ WARNING

The retaining strap MUST be fed through the adjustable end of the battery box

retaining strap buckle as shown in FIGURE 11.8.

NOTE: Take note of the position and orientation of the battery box retaining strap as it passes

through the slots of the battery tray and the adjustable end of the battery box retraining strap

buckle.

1/4-20 x 7/8-Inch

Hex Flange Screw

Detail “A” - Dual UI Batteries

NEGATIVE (-)

Terminal/Post

1/4-20

Hex

Flange

Locknut

POSITIVE (+)

Terminal/Post

Connect Cable

Ring Terminal

to This Side of

Terminal/Post

POSITIVE (+)

Terminal/Post

NEGATIVE (-)

Terminal/Post

GREY

Terminal

Cap

ORANGE

Terminal Cap

Tie-Wraps

Detail “B” - Installing Battery Terminal Cap onto Battery Cable

Cable

Terminal Cap

NOTE: For clarity, only one cable

and terminal cap are shown. Both

caps install in the same manner.

Advertising