Selecting a Crossover/Pass-Through Connection

Once a FiberLinX is installed, you can select a crossover workstation or

pass-through repeater/hub connection for the twisted pair data port.

FiberLinX’s twisted pair data port has one RJ-45 connector for a single

shielded or unshielded twisted pair link segment and features a push-button

switch, located next to the port, for selecting the type of connection.

To select a pass-through connection on FiberLinX, simply press the push-

button IN. A crossover connection is selected when the push-button is OUT.

NOTE: If uncertain whether a crossover or pass-through connection is

needed, set the switch to the position that makes the TP data port link LED
glow.

LED Operation

FiberLinX features diagnostic LEDs for each port. The following illustration

shows the location of the LEDs on FiberLinX.

LEDs for the Fiber Data Port

LED functions for the fiber data port are as follows:

FDX

Glows yellow when FDX is selected on port.

ACT

Blinks green when data is detected on the

port.

LNK

Glows green when a link is established.

FA

Glows green when FiberAlert is enabled.

LEDs for the Twisted Pair Data Port

LED functions for the twisted pair data port are as follows:

LNK

Glows green when a link is established.

FDX

Glows yellow when FDX is selected on the

port.

LEDs for the Twisted Pair Management Port

LED functions for the twisted pair management port are as

follows:

LNK

Glows green when a link is established.

FDX

Glows yellow when FDX is selected on the

port.

FAR CPU

UP

Glows yellow when far end is detected.

2.5

Figure 2.2

FiberLinX LEDs