Problem Determination
ida ReRouter

63

ROUT0035E:

Cannot open configuration file [...]

Description:

The system is not properly configured.
The configuration file "idaRoute.ini" is not created
in the idaRoute directory.

Action:

Use the idaRCtrl program to make the proper setup.

Note:

-

ROUT0052E:

Configuration error for entry [...]

Description:

A configuration error has been found - [...]
identifies the wrong keyword.

Action:

Correct the entry, using the idaRCtrl.

Note:

-

ROUT0104E:

No reply generated from remote device [...]

Description:

The printer application (e.g. HOST-PSF or
idaPSS) has requested an ACK. However, the

remote device has not answered before a timeout
has occurred.

Action:

Check the connection to the remote device, reset
the device and try once more.

Note:

-

ROUT0105E:

APPC communication error

Description:

A communication error has occurred. An invalid
or unsupported status return code is sent from

APPC API.

Action:

The transaction program is terminated. To re-start
the communication, operate/re-start the printer.
If the problem persists, contact your system administrator..

Note:

-

ROUT0106E:

APPC allocation error [...]

Description:

The transaction program has discovered an allocation
error.

Action:

The TP (transaction program) is not configured in

the setup for the Communications Manager/2.

Enter CM/2 and correct the TP.

or
- no allocation is pending in the program. The

program has been started manually.

Note:

-

Advertising