Figure 10. no-delay shutter, Figure 11. no-delay shutter and read-out inhibit, Figure 10 – JAI TM-1020 User Manual

Page 32: No-delay shutter, Figure 11, No-delay shutter and read-out inhibit

Advertising
background image

Page 22
TM-1020 Series Progressive Scan Shutter Cameras

Operation

FIGURE 10.

No-Delay Shutter

FIGURE 11.

No-Delay Shutter and Read-Out Inhibit

The TM-1020A series also has read-out-inhibit control (ROI) to control the vertical clock start (Async
Shutter #9). When ROI is low, V-clock is stopped and the transferred charges remain in the vertical shift
registers, which work like CCD memory. When the ROI is high, it clocks out the CCD data. This helps
a single frame grabber process multiple images in pipeline processing (sequential process).

EXT. VINIT (Pulse width control)

HD

INT. VINIT after trailing edge of EXT. VINIT

Discharge

Transfer Gate

FDV

Analog Video Sync

Exposure time set by pulse width

41H

Vsync

VINIT (External Pulse Width Control Trigger)

No-Delay Shutter (All cameras)

No-delay Exposure

Discharge

Transfer Gate

ROI Control: Camera #1

Camera #1 Video

ROI Control: Camera #2

Camera #2 Video

ROI pulse width: Min. 1H to 1frame

Max. 1H delay

FDV/Vsync