6 appendix, 1 specifications, Specifications – JAI TM-1020 User Manual

Page 48: Table 8, Tm-1020 series camera specifications table, 6appendix

Advertising
background image

Page 38
TM-1020 Series Progressive Scan Shutter Cameras

Appendix

6

Appendix

6.1 Specifications

TABLE 8.

TM-1020 Series Camera Specifications Table

Feature

TM-1020-15

TM-1020-15CL

TM-1020A-15

TM-1020-30

TM-1020-30CL

Imager

1" (9.1mm x 9.2mm) progressive scan interline transfer CCD

Pixels

1024 (H) x 1024 (V), 1008 x 1018 active

Cell size

9.0µm x 9.0µm

Scanning

1050 lines at 15Hz; 1024 x 512 lines at

30Hz (two-row binning)

1050 lines at 30Hz

Partial scan: 500L at 58Hz

: 250L at 102Hz

Sync

Internal/external auto switch

HD/VD, 4.0 Vp-p impedance 4.7K

Ω

VD=15Hz±5%, non-interlace

HD=15.734kHz±5%

Internal/external auto switch

HD/VD, 4.0 Vp-p impedance 4.7K

Ω

VD=30Hz±5%, non-interlace

HD=31.47kHz±5%

Data clock output

20.000 MHz

40.000 MHz

Resolution

Digital: 1008 (H) x 1018 (V),

(Analog: over 700 TV lines (H) x 800 TV lines (V))

S/N ratio

50dB min. (AGC: off)

Min. illumination

1.0 lux with factory defaults: f=1.4 without IR cut filter (no shutter)

Sensitivity: 12µV/ e-

Video output

Analog: 1.0 Vp-p composite video, 75

Ω

Digital output: 8-bit RS-644
(TM-1020-15: 12S-RS-422)

Camera Link (CL models only)

Analog: 1.0 Vp-p composite video, 75

Ω

Digital output: 8-bit RS-644

Camera Link (CL model only)

AGC

Not available

Gamma

Programmable LUT (1.0 std.)

Lens mount

C-mount (use 1" format lenses)

Power requirement

12V DC, 500mA (current measured at 25°)

Operating temp.

-10°C to 45°C

*

Random vibration

7 Grms (10Hz to 2000Hz)

Shock

70G, 10-11msec

Size (W x H x L)

44mm x 44mm 64mm (1.75" x 1.75" x 2.50")

Weight

Std. version:133 grams, 4.7 oz. (without tripod)
CL version: 137 grams, 4.8 oz. (without tripod)

tripod weight: 13.8 grams 0.5 oz.

Power cable

12P-02S (optional)