4 lvds-version camera rs-232 commands, Table 7. rs-232 command list, Table 7 – JAI TM-1020 User Manual

Page 44: Rs-232 command list, 4lvds-version camera rs-232 commands

Advertising
background image

Page 34
TM-1020 Series Progressive Scan Shutter Cameras

LVDS-Version Camera RS-232 Commands

4

LVDS-Version Camera RS-232 Commands

The LVDS-version camera can be controlled via RS-232 commands. The Start character is always “:”
and the end character is always “CR” (return). For example, to set Asynchronous Pulse Width Mode,
send the command :SA9”CR” to the camera. The following table contains RS-232 commands that can
be used to control the camera.

TABLE 7.

RS-232 Command List

First

Character

Second

Character

Third

Character

Response

Functions

1

“S” (shutter)

“M” (Manual)

“0” - “9”
Mode

ACK

Manual Shutter Mode

“A” (ASYNC)

“0” - “8”
Mode

ACK

Async Shutter Mode

“9” (Pulse
Width Mode)

ACK

Async Pulse Width Mode

2

“G” (Gain)

“M”

“00” - “FF”

ACK

Gain Control

3

“V” (A/D Vref)

“T” (Top)

“00” - “FF”

ACK

Vtop reference setting

“B” (Bottom)

“00” - “FF”

ACK

Vbtm reference setting

4

“W” (Write)

“P” (Page)

“0” - “6”

ACK

Write current setting to Page
EEPROM

“U” (User)

“A” - “D”

ACK

Write current setting to User
EEPROM

“S” (System)

“A” - “D”

ACK

Write current setting to System
EEPROM

5

“L”

“P” (Page)

“0” - “6”

ACK

Restore setting from Page
EEPROM

“U” (User)

“A” - “D”

ACK

Restore setting from User
EEPROM

“S” (System)

“A” - “D”

ACK

Restore setting from System
EEPROM

“N” (kNee)

“0” - “9”

ACK

Load Preset Knee Table

6

“R” (Report)

“P” (Page)

“0” - “6”

ACK

ACK + “P” + (“9” - “F”) + 16
bytes

“U” (User)

“A” - “D”

ACK

ACK + “U” + (“A” - “D”) + 6
bytes

“S” (System)

“A” - “D”

ACK

ACK + “S” + (“A” - “D”) + (6
bytes)

“R” (Current)

ACK

ACK + “RR” + 16 bytes

“X” (Execute)

ACK

Set Camera with loaded data

“D” (Date)

info

Report CPU program version

Advertising