Wiring connections – Sierra FLAT-TRAKTM 780S User Manual

Page 16

Advertising
background image

Chapter 2 Installation

Series 780S Instruction Manual

2-4

IM-78S-B

Wiring Connections

For NEMA 4X enclosures, use TB2 for power and signal connec-
tions, TB1 is for sensor connections. (The terminal designations are
labeled inside the enclosure cover.)

Wiring connections
inside cover

To access components:
1. Loosen 4 screws.
2. Remove cover.

NEMA 4X enclosure

terminal blocks

TB1

TB2

1
3
5
7
9

11
13
15

2
4
6
8

10
12
14
16

6
4
2

5
3
1

Figure 2-2. Wiring Access NEMA 4X Enclosures

For Hazardous-Area enclosures, use the terminal blocks located in-
side the smaller end of the flow meter enclosure for all wiring con-
nections. (The terminal designations are labeled inside the enclosure
cover.) Make sure to observe all CE compliance requirements for
AC wiring connections given on the next page.

Hazardous-Area enclosure

terminal blocks

Set screw

Wiring
connections

To access components:
1. Use 1/16 inch hex key to loosen set screw.
2. Turn cover counterclockwise to remove.

1
2
3
4
5
6
7
8
9

10

20
19
18
17
16
15
14
13
12
11

Figure 2-3. Wiring Access Hazardous-Area Enclosures

Warning!

To avoid potential electric

shock, follow National Elec-
tric Code safety practices or

your local code when wiring

this unit to a power source

and to peripheral devices.

Failure to do so could result

in injury or death. All AC

power connections must be

in accordance with pub-

lished CE directives.