Specifications, 3) other component specifications (a) outdoor unit – Sanyo CL2462R User Manual

Page 11

Advertising
background image

– 11 –

SM830092

2. SPECIFICATIONS

(3)

Other Component Specifications

(A)

Outdoor Unit

MODEL No.

C2462R

Compressor Motor Magnetic Contactor

FC - 1SUL

Coil rated

AC 240 V, 60 Hz

Coil resistance (at 68

°

F)

587

±

5 %

Contact rated (Main)

AC 240 V, 26 A

Contact rated (Auxiliary)

AC 240 V, 3 A

Power Relay

HH62S

Coil rated

AC 240 V, 60 Hz

Coil resistance (at 68

°

F)

k

17.2

Contact rated

AC 220 V, 5 A

Thermostat (Coil sensor)

YTB - 4U305F

Operating Temperature

°

F

79

±

3 OFF

75 ON

Contact rated

200 to 240 V, 1 A

+ 3
– 1

Advertising