Specifications, 3) other component specifications (b) outdoor unit – Sanyo CL2462R User Manual

Page 12

Advertising
background image

– 12 –

SM830092

2. SPECIFICATIONS

(3)

Other Component Specifications

(B)

Outdoor Unit

MODEL No.

CL2462R

Compressor Motor Magnetic Contactor

FC - 1SUL

Coil rated

AC 240 V, 60 Hz

Coil resistance (at 77

°

F)

587

±

5 %

Contact rated (Main)

AC 240 V, 26 A

Contact rated (Auxiliary)

AC 240 V, 3 A

Power Relay

HH62S

Coil rated

AC 240 V, 60 Hz

Coil resistance (at 77

°

F)

k

17.2

Contact rated

AC 220 V, 5 A

Power Transformer

ATR - I35B

Rated

Primary

AC 220 V, 60 Hz

Secondary

14 V, 0.2 A

Capacity

2.8 VAC

Coil resistance (at 78

°

F )

WHT – WHT : 482.5

,

BRN – BRN : 3.95

Thermal cut off temperature

°

F

266

Thermistor (Outdoor Temp. sensor)

PBC - 41E - S4

Coil resistance

k

14

°

F : 23.7

,

50

°

F : 9.7

23

°

F : 18.8

,

68

°

F : 6.5

32

°

F : 15.0

,

86

°

F : 4.4

41

°

F : 12.1

,

104

°

F : 3.1

113

°

F : 2.6

Solenoid control valve or coil

Solenoid control valve

VPV - 202DQ50

Solenoid coil

VPV - MOAQ517B1

Advertising