10-8

Sun Fire V120 and Netra 120 Server User’s Guide • December 2001

10.2

Additional Diagnostic Tests for Specific
Devices

10.2.1

Using the

probe-scsi

Command To Confirm

That Hard Disk Drives Are Active

The

probe-scsi

command transmits an inquiry to SCSI devices connected to the

system’s internal SCSI interface. If a SCSI device is connected and active, the
command displays the unit number, device type, and manufacturer name for that
device.

The

probe-scsi-all

command transmits an inquiry to all SCSI devices connected

to both the system’s internal and its external SCSI interfaces.

FIGURE 10-3

shows

sample output from a Sun Fire V120 with no externally connected SCSI devices but
containing two 36 GB Hard Disk Drives, both of them active.

FIGURE 10-2

probe-scsi

Output Message

ok probe-scsi

Target 0

Unit 0 Disk SEAGATE ST336605LSUN36G 4207

Target 1

Unit 0 Disk SEAGATE ST336605LSUN36G 0136

FIGURE 10-3

probe-scsi-all

Output Message

ok probe-scsi-all

/pci@1f,0/pci@1/scsi@8,1

/pci@1f,0/pci@1/scsi@8

Target 0

Unit 0 Disk SEAGATE ST336605LSUN36G 4207

Target 1

Unit 0 Disk SEAGATE ST336605LSUN36G 0136