3-23. When Using Wireless Remote Controller Instead of Wired Remote Controller
When the wireless remote controller is to be used, slide the switch on the indoor unit control PCB.
• If this setting is not made, an alarm will occur. (The operation lamp on the display blinks.)
• This setting is not necessary if both the wired remote controller and wireless remote controller are used.
• The location of the switch varies depending on the type of PCB used. Check the model name before making the
setting.
KHX1862 / 1962
Setting at time of
factory shipment
Slide No. 3 on SW101
from ON OFF.
CR-KR254GXH56A-0
NOTE
This setting is necessary also in case of “non-using wired/wireless” remote controller.