Sanyo ECO R410A User Manual

Page 36

Advertising
background image

36

Fig. 4-4

Stranded wire

Ring
pressure
terminal

Str

ip 3/8 in.

Fig. 4-5

Wire

Special
washer

Screw

Ring pressure
terminal

Terminal plate

Screw and
Special washer

Ring
pressure
terminal

Wire

WARNING

Loose wiring may cause the

terminal to overheat or result

in unit malfunction. A fire

hazard may also exist.

Therefore, ensure that all wir-

ing is tightly connected.

When connecting each power wire to the terminal, fol-

low the instructions on “How to connect wiring to the

terminal” and fasten the wire securely with the fixing

screw of the terminal plate.

How to connect wiring to the terminal

For stranded wiring

(1) Cut the wire end with cutting pliers, then strip the

insulation to expose the stranded wiring approx.

3/8 in. and tightly twist the wire ends. (Fig. 4-4)

(2) Using a Phillips head screwdriver, remove the termi-

nal screw(s) on the terminal plate.

(3) Using a ring connector fastener or pliers, securely

clamp each stripped wire end with a ring pressure

terminal.

(4) Place the ring pressure terminal, and replace and

tighten the removed terminal screw using a screw-

driver. (Fig. 4-5)

Advertising