DS6708 Digital Scanner Product Reference Guide

Undecoded Scanner Emulation

Beep Style

Beep on Successful Transmit

11-4

Parameter Pass-Through

Parameter Process and Pass
Through

11-5

Convert Newer Code Types

Convert Newer Code Types

11-5

Module Width

20 µs

11-6

Convert All Bar Codes to Code 39

Do Not Convert to Code 39

11-7

Code 39 Full ASCII Conversion

Disable

11-7

Transmission Timeout

3 seconds

11-8

Ignore Unknown Characters

Ignore Unknown Characters

11-9

Leading Margin

2 ms

11-9

Check for Decode LED

Check for Decode LED

11-10

123Scan Configuration Tool

123Scan Configuration

None

1

12-2

UPC/EAN

UPC-A

01h

Enable

13-6

UPC-E

02h

Enable

13-6

UPC-E1

0Ch

Disable

13-7

EAN-8/JAN 8

04h

Enable

13-7

EAN-13/JAN 13

03h

Enable

13-8

Bookland EAN

53h

Disable

13-8

Decode UPC/EAN/JAN Supplementals (2
and 5 digits)

10h

Ignore

13-9

UPC/EAN/JAN Supplemental Redundancy

50h

10

13-10

Transmit UPC-A Check Digit

28h

Enable

13-11

Transmit UPC-E Check Digit

29h

Enable

13-11

Transmit UPC-E1 Check Digit

2Ah

Enable

13-12

UPC-A Preamble

22h

System Character

13-13

UPC-E Preamble

23h

System Character

13-14

Table A-1

Standard Default Parameters Table (Continued)

Parameter

Parameter

Number

Default

Page