DS6708 Digital Scanner Product Reference Guide

Illumination Bank Control

Parameter # F1h 3Bh

Selecting an illumination bank control parameter allows the user to control the illumination banks on the scan
engine.

Full

(0) (default): The full illumination system is enabled.

Auto (1): The illumination system automatically switches from left to right banks.

Left

(2): The left bank is enabled.

Right (3): The right bank is enabled.

*

Full Illumination

(00h)

Auto Illumination

(01h)

Left Illumination

(02h)

Right Illumination

(03h)