4. heating capacity – Sanyo KHS2472 User Manual

Page 27

Advertising
background image

Indoor Unit

: KHS1872

Outdoor Unit : CH1872
Power Supply : 230V Single Phase 60Hz

< Heating Capacity >

5-4. Heating Capacity

TH : Total Heating Capacity (BTU/h)

1. Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) D.B.

: Outdoor Ambient Temp. 47 °F (8.3 °C) D.B. / 43 °F (6.1 °C) W.B.

2.

3. Above data represents the value when the operation frequency of a compressor is fixed.

Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air

Prevention Protection during heating operation into account. For this reason, the value may vary

from the actual heating characteristics.

NOTE

RATING CAPACITY:

20,400 BTU/h

AIR FLOW RATE:

541 CFM

OUTDOOR

INDOOR

ENT. TEMP.

o

F (

o

C)

AMBIENT TEMP.

o

F (

o

C)

W.B.

60

65

70

75

80

(15.6)

(18.3)

(21.1)

(23.9)

(26.7)

0 (-17.8)

TH

11,320

11,320

11,310

11,290

11,270

3 (-16.1)

TH

11,700

11,700

11,690

11,680

11,650

8 (-13.3)

TH

12,620

12,610

12,600

12,590

12,560

13 (-10.6)

TH

13,570

13,560

13,550

13,530

13,510

18 (-7.8)

TH

14,610

14,610

14,590

14,570

14,540

23 (-5.0)

TH

15,710

15,700

15,690

15,660

15,630

28 (-2.2)

TH

16,850

16,840

16,830

16,800

16,760

33 (0.6)

TH

18,030

18,020

18,000

17,970

17,930

38 (3.3)

TH

19,200

19,190

19,170

19,130

19,090

43 (6.1)

TH

20,440

20,430

# 20,400

20,360

20,310

48 (8.9)

TH

21,700

21,680

21,650

21,600

21,550

53 (11.7)

TH

22,970

22,940

22,910

22,860

22,790

58 (14.4)

TH

24,190

24,160

24,120

24,060

23,990

63 (17.2)

TH

25,450

25,410

25,360

25,300

25,220

65 (18.3)

TH

25,930

25,900

25,850

25,780

25,700

27

Advertising
This manual is related to the following products: