Sanyo KHS2472 User Manual

Page 28

Advertising
background image

Indoor Unit

: KHS2472

Outdoor Unit : CH2472
Power Supply : 230V Single Phase 60Hz

< Heating Capacity >

TH : Total Heating Capacity (BTU/h)

1. Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) D.B.

: Outdoor Ambient Temp. 47 °F (8.3 °C) D.B. / 43 °F (6.1 °C) W.B.

2.

3. Above data represents the value when the operation frequency of a compressor is fixed.

Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air

Prevention Protection during heating operation into account. For this reason, the value may vary

from the actual heating characteristics.

NOTE

RATING CAPACITY:

29,000 BTU/h

AIR FLOW RATE:

653 CFM

OUTDOOR

INDOOR

ENT. TEMP.

o

F (

o

C)

AMBIENT TEMP.

o

F (

o

C)

W.B.

60

65

70

75

80

(15.6)

(18.3)

(21.1)

(23.9)

(26.7)

0 (-17.8)

TH

16,210

16,210

16,200

16,180

16,150

3 (-16.1)

TH

16,750

16,750

16,740

16,720

16,690

8 (-13.3)

TH

18,050

18,050

18,040

18,010

17,980

13 (-10.6)

TH

19,390

19,390

19,380

19,350

19,320

18 (-7.8)

TH

20,870

20,860

20,850

20,820

20,780

23 (-5.0)

TH

22,420

22,410

22,390

22,360

22,320

28 (-2.2)

TH

24,030

24,020

24,000

23,960

23,910

33 (0.6)

TH

25,690

25,680

25,650

25,610

25,550

38 (3.3)

TH

27,330

27,320

27,280

27,230

27,160

43 (6.1)

TH

29,070

29,040

# 29,000

28,940

28,860

48 (8.9)

TH

30,820

30,790

30,740

30,670

30,580

53 (11.7)

TH

32,580

32,540

32,470

32,390

32,300

58 (14.4)

TH

34,260

34,210

34,140

34,050

32,390

63 (17.2)

TH

35,980

35,920

35,840

33,980

32,250

65 (18.3)

TH

36,640

36,580

35,780

33,880

32,150