Operation with the Remote Control Unit (continued)

5. Night Setback Mode

Night Setback Mode is used for saving energy.

Press the NIGHT SETBACK button while operation.
The

mark appears in the display.

To release the night setback function, press the NIGHT SETBACK button again.

A. In Cooling and DRY

Mode: (

and )

B. In Heating Mode: (

)

When the night setback mode is selected, the air conditioner automatically
raises the temperature setting 2 °F when 30 minutes have passed after the
selection was made, and then another 2 °F after another 30 minutes have
passed, regardless of the indoor temperature when night setback was
selected. This enables you to save energy without sacrificing comfort. This
function is convenient when gentle cooling is needed.

Setting
temperature

Press the NIGHT
SETBACK button

30 min.

30 min.

Time

2 °F

2 °F

When the night setback mode is selected, the air conditioner automatically
lowers the temperature setting 4 °F when 30 minutes have passed after the
selection was made, and then another 4 °F after another 30 minutes have
passed, regardless of the indoor temperature when night setback was
selected. This enables you to save energy without sacrificing comfort. This
function is convenient when gentle heating is needed.

Setting
temperature

Press the NIGHT
SETBACK button

30 min.

30 min.

Time

4 °F

4 °F