SPC3

PROFIBUS Interface Center

SPC3 Hardware Description

V1.3

Page 13

Copyright (C) Siemens AG 2003 All rights reserved.

2003/04

4.2 Processor Parameters (Latches/Register)

These cells can be either read only or written only. SPC3 carries out “address swapping” for an access to
the address area 00H - 07H (word register) in the Motorola mode. That is, the SPC3 exchanges

address bit 0 (generated from an even address, one uneven, and vice-versa). The following sections more
clearly explain the significance of the individual registers.


Address
Intel / Motorla

Name Bit
No.

Significance (Read Access!)

00H

01H

Int-Req-Reg
7..0

Interrupt Controller Register

01H

00H

Int-Req-Reg
15..8

02H

03H

Int—Reg
7..0

03H

02H

Int—Reg
15..8

04H

05H

Status-Reg
7..0

Status Register

05H

04H

Status-Reg
15..8

06H

07H

Reserved

07H

06H

08H

DIN_Buffer_SM
7..0

Buffer assignment of the
DP_Din_Buffer_State_Machine

09H

New_DIN_Buffer_Cmd
1..0

The user makes a new DP Din buffer available in
the N state.

0AH

DOUT_Buffer_SM
7..0

Buffer assignment of the
DP_Dout_Puffer_State_Machine

0BH

Next_DOUT_Buffer_Cmd
1..0

The user fetches the last DP Dout-Buffer from the N
state.

0CH

DIAG_Buffer_SM
3..0

Buffer assignment for the
DP_Diag_Puffer_State_Machine

0DH

New_DIAG_Puffer_Cmd
1..0

The user makes a new DP Diag Buffer available to
the SPC3.

0EH

User_Prm_Data_OK
1..0

The user positively acknowledges the user
parameter setting data of a Set_Param-Telegram.

0FH

UserPrmDataNOK
1..0

The user negatively acknowledges the user
parameter setting data of a Set_Param-Telegram.

10H

User_Cfg_Data_OK
1..0

The user positively acknowledges the configuration
data of a Check_Config-Telegram.

11H

User_Cfg_Data_NOK 1..0 The user negatively acknowledges the configuration

data of a Check_Config-Telegram.

12H

Reserved

13H

14H

SSA_Bufferfreecmd

The user has fetched the data from the SSA buffer
and enables the buffer again.

15H

Reserved

Figure 4.2: Assignment of the Internal Parameter Latches for READ