SPC3

PROFIBUS Interface Center

SPC3 Hardware Description

V1.3

Page 35

Copyright (C) Siemens AG 2003 All rights reserved.

2003/04


Address

Bit Position

Designation

Control
Register

7

6

5

4

3

2

0

08H

F

U

N

D

Din_Buffer_SM

X1

X2

X1

X2

X1

X2

X1

X2 See below for coding.

X1

X2 Coding

0

0

Nil

0

1

Din_Buf_Ptr1

1

0

Din_Buf_Ptr2

1

1

Din_Buf_Ptr3


Figure 6.13: Din_Buffer Management

When reading the ‘New_Din_Buffer_Cmd’ the user gets the information which buffer (U-buffer) belongs to
the user after the change (Din_Buf_Ptr 1-3).

Address

Bit Position

Designation

Control
Register

7

6

5

4

3

2

1

0

09H

0

0

0

0

0

0

New_Din_Buf_Cmd

0

1

Din_Buf_Ptr1

1

0

Din_Buf_Ptr2

1

1

Din_Buf_Ptr3

Figure 6.14: Next_Din_Buffer_Cmd

6.2.5.3 User_Watchdog_Timer

After power-up (‘DATA_EX’ state), it is possible that SPC3 continually answers Write_Read_Data-telegrams
without the user fetching the received Din buffers or making new Dout buffers available. If the user
processor ‘hangs up,’ the master would not receive this information. Therefore, a ‘User_Watchdog_Timer’
is implemented in SPC3.

This User_Wd_Timer is an internal 16-bit RAM cell that is started from a ‘R_User_Wd_Value

15..0

’ value the

user parameterizes and is decremented with each received Write_Read_Data telegram from SPC3. If the
timer attains the ‘0000hex’ value, SPC3 transitions to the ‘Wait_Prm’ state, and the DP_SM carries out a
‘Leave_Master.’ The user must cyclically set this timer to its start value. Therefore, ‘Res_User_Wd = 1’
must be set in mode register 1. Upon receipt of the next Write_Read_Data telegram, SPC3 again loads the
User_Wd_Timer to the parameterized value ‘R_User_Wd_Value

15..0

’ and sets ‘Res_User_Wd = 0’ (Mode

Register 1). During power-up, the user must also set ‘Res_User_Wd = 1’, so that the User_Wd_Timer is
even set at its parameterized value.

6.2.6 Global_Control (SAP58)

SPC3 itself processes the Global_Control-Telegrams in the manner already described. In addition, this
information is available to the user.

The first byte of a valid Global_Control command is stored in the R_GC_Comand RAM cell. The second
telegram byte (Group_Select) is processed internally.

Address

Bit Position

Designation

RAM
Cell

7

6

5

4

3

2

1

0

3CH

Res

Res

Sync

Un

sync

Freeze

Un

freeze

Clear_

Data

Res

R_GC_Command