SPC3

PROFIBUS Interface Center

SPC3 Hardware Description

V1.3

Page 23

Copyright (C) Siemens AG 2003 All rights reserved.

2003/04


Bit 0

MAC_Reset

After it processes the current request, the SPC3 has arrived at the offline state (through
setting the ‘Go_Offline bit’ or through a RAM access violation).

Bit 1

Go/Leave_DATA_EX

The DP_SM has entered or exited the ‘DATA_EX’ state.

Bit 2

Baudrate_Detect

The SPC3 has exited the ‘Baud_Search state’ and found a baud rate.

Bit 3

WD_DP_Control_Timeout

The watchdog timer has run out in the ‘DP_Control’ WD state.

Bit 4

User_Timer_Clock

The time base for the User_Timer_Clocks has run out (1/10ms).

Bit 5

Res

For additional functions

Bit 6

Res

For additional functions

Bit 7

Res

For additional functions

Bit 8

New_GC_Command

The SPC3 has received a ‘Global_Control telegram’ with a changed ‘GC_Command-
Byte,’ and this byte is stored in the ‘R_GC_Command’ RAM cell.

Bit 9

New_SSA_Data

The SPC3 has received a ‘Set_Slave_Address telegram’ and made the data available
in the SSA buffer.

Bit 10

New_Cfg_Data

The SPC3 has received a ‘Check_Cfg telegram’ and made the data available in the Cfg
buffer.

Bit 11

New_Prm_Data

The SPC3 has received a ‘Set_Param telegram’ and made the data available in the
Prm buffer.

Bit 12

Diag_Puffer_Changed

Due to the request made by ‘New_Diag_Cmd,’ SPC3 exchanged the diagnostics buffer
and again made the old buffer available to the user.

Bit 13

DX_OUT

The SPC3 has received a ‘Write_Read_Data telegram’ and made the new output data
available in the N buffer. For a ‘Power_On’ or for a ‘Leave_Master,’ the SPC3 deletes
the N buffer and also generates this interrupt.

Bit 14

Res

For additional functions

Bit 15

Res

For additional functions


Figure 5.4: Interrupt Request Register, IRR Bit 15..0 (writable and readable)