SPC3

PROFIBUS Interface Center

SPC3 Hardware Description

V1.3

Page 49

Copyright (C) Siemens AG 2003 All rights reserved.

2003/04

8.5.3 Timing in the Asynchronous Intel Mode (X86 Mode) :

In 80X86 operation, SPC3 acts like memory with ready logic. The access times depend on the type of
accesses.

The request for an access to SPC3 is generated from the negative edge of the read signal or the positive
edge of the write signal.

SPC3 generates the Ready signal synchronously to the fed in pulse. The Ready signal is reset when the
read signal or write signal is deactivated. The data bus is switched to the Tristate with XRD = 1.

AMI-Vers.

ST-Vers.

No.

Parameter

Min

Max

Min

Max

Unit

20

Address-Setuptime to RXD

or XWR

0

0

ns

21

XRD

to Data valid (Zugriff auf RAM)

4T+5

(88,3)

3T+42.5

(105)

ns

XRD

to Data valid (Zugriff auf die Register)

4T+18

(101,3)

4T+20.2

(103,5)

ns

22

Address (AB

10..0

) Holdtime after XRD or XWR

0

0

ns

23

XCS

Setuptime to XRD

or XWR

- 5

-5

ns

24

XRD-Puls-Width

6T – 10

(115)

6T

10

(115)

ns

25

Data Holdtime after XRD

2

6

3.1

10.2

ns

26

Read/Write-Inactive-Time

10

10

ns

27

XCS Holdtime after XRD

or XWR

0

0

ns

28

XRD/XWR

to XRDY

(Normal Ready)

4T + 5

5T+ 14

5T + 16

ns

29

XRD/XWR

to XRDY

(Early Ready)

3T + 5

4T+ 14

4T + 12

ns

30

XREADY-Holdtime after XRD or XWR

4.3

12.8

6

22

ns

31

Data Setuptime to XWR

10

10

ns

32

Data Holdtime after XWR

10

10

ns

33

XWR-Pulse-Width *

4T

4T

ns

34

XRD, XWR Cycletime

6T

6T

ns

35

last XRD to XCS

4T + 10

4T + 10

ns

36

XCS to next XWR

2T + 10

2T + 10

ns

37

XWR to next XWR (XCS don’t care)

6T

6T

ns



Explanations:

T

=

Clock pulse cycle (48MHz)

TBD

=

to be defined

(1

=

Access to the RAM

(2

=

Access to the registers/latches

(3

=

For T = 48 MHz