Spc3 profibus interface center – Siemens SPC3 User Manual

Page 23

Advertising
background image

SPC3

PROFIBUS Interface Center

SPC3 Hardware Description

V1.3

Page 21

Copyright (C) Siemens AG 2003 All rights reserved.

2003/04


Bit 0

Offline/Passive-Idle

Offline-/Passive-Idle state

0 =

SPC3 is in offline.

1 =

SPC3 is in passive idle.

Bit 1

FDL_IND_ST

FDL indication is temporarily buffered.

0 =

No FDL indication is temporarily buffered.

1 =

No FDL indication is temporarily buffered.

Bit 2

Diag_Flag

Status diagnostics buffer

0 =

The DP master fetches the diagnostics buffer.

1 =

The DP master has not yet fetched the diagnostics buffer.

Bit 3

RAM Access Violation

Memory access > 1.5kByte

0 =

No address violation

1 =

For addresses > 1536 bytes, 1024 is subtracted from the current address,
and there is access to this new address.

Bits
4,5

DP-State

1..0

DP-State Machine state

00 = ’Wait_Prm’ state

01= ’Wait_Cfg’ state

10 = ’DATA_EX’ state

11= Not possible

Bits
6,7

WD-State

1..0

Watchdog-State-Machine state

00 = ’Baud_Search’ state

01= ’Baud_Control’ state

10 = ’DP_Control’ state

11= Not possible

Bits
8,9

Baud rate

3..0

:

10,11

The baud rates SPC3 found

0000 = 12 MBaud

0001 = 6 MBaud

0010 = 3 MBaud

0011 = 1.5 MBaud

0100 = 500 kBaud

0101 = 187.5 kBaud

0110 = 93.75 kBaud

0111 = 45.45 kBaud

1000 = 19.2 kBaud

1001 = 9.6 kBaud

Rest =

Not possible

Bit 12

SPC3-Release

3..0

:

13,14,

Release no. for SPC3

15

0000 = Release 0

Rest =

Not possible


Figure 5.3: Status Register Bit15 .. 0.(readable)