2-2. outdoor unit – Sanyo CH1852 User Manual

Page 12

Advertising
background image

8

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

2-2-2. Outdoor Unit

(1) Outdoor unit CH0951

Control PCB

Part No.

POW-CH095

Controls

Control circuit fuse

Compressor

Type

Rotary (Hermetic)

Compressor model

C-1R75H2R

Nominal output

W

750

Compressor oil … Amount

cc

SUNISO 4GSD-T … 350

Coil resistance (ambient temp. 68°F (20°C))

C – R: 0.841

C – S: 2.831

Safety devices

Type

External (OLR)

Overload relay

MRA99111-9200

Run capacitor

µF

40

VAC

400

Crank case heater

115V, 20W

Fan & Fan Motor

Type

Propeller

Q’ty … Dia. and length

inch. (mm)

1 … 16-17/32 (ø 420)

Fan motor model … Q’ty

UE6-21BA1PA … 1

No. of poles … rpm (115V, High)

6 … 630

Nominal output

W

20

Coil resistance (ambient temp. 68°F (20°C))

BLU – BRN: 45.3

BLU – PNK: 50.5

Run capacitor

µF

8

VAC

220

Heat Exchanger Coil

Coil

Aluminum plate fin / Copper tube

Rows

2

Fin pitch

inch (mm)

1/16 (1.4)

Face area

ft

2

(m

2

)

3.37 (0.313)

External Finish

Acrylic baked-on enamel finish

000-111

SM

(1-17)

00.3.17

11:44

AM

y [ W 8

Advertising