9-2. Air conditioner does not operate.

9-2-1. Circuit breaker trips (or fuse blows).

A. When the circuit breaker is set to ON, it is tripped soon. (Resetting is not possible.)

There is a possibility of ground fault.

Check insulation resistance.

If resistance value is 2M

½

or less, insulation is defective (“NO”).

Measure insulation
resistance of electrical
parts in outdoor unit.

NO

NO

Set circuit breaker to OFF.

*

Measure insulation
resistance of electrical
parts in indoor unit.

1

Remove both power supply wires
and inter-unit wires from terminal
plate in outdoor unit.
Measure insulation resistance
of outdoor unit.

2

Remove inter-unit wires from
terminal plate in indoor unit.
Measure insulation resistance
of indoor unit.

Insulation of
outdoor unit
is defective.

Insulation of
indoor unit
is defective.