Sanyo CH1852 User Manual

Page 64

Advertising
background image

60

9-3-4. Only outdoor fan does not run.

9-3-5. Only compressor does not run.

• Check compressor motor

capacitor.

• Measure resistance of PTC

thermistor.

• Measure resistance of

compressor motor winding.

• Measure resistance of power

relay. (PR)

NO

YES

YES

Overload relay is working.

YES

Temperature of compressor
is abnormally high.

Refrigerant gas shortage.

Charge refrigerant gas (R22).

Rotor may be locked up.

• Measure Power supply

voltage.
The voltage is too low.

No

Fan cannot
be turned.

OK

• Check fan rotation.

Turn fan gently once or twice by
hand.

• Check fan casing

foreign matter on
inside.

Fan motor burnout
or foreign matter in
bearings.

Remove foreign
matter or repair.

Repair or replace.

• Measure resistance of indoor fan

motor winding.

• Check fan motor capacitor.

000-111

SM

(18-68)

00.3.17

11:49

AM

y [ W 60

Advertising
This manual is related to the following products: