Checking electrical components, 1. measurement of insulation resistance, 1-1. power supply wires – Sanyo CH1852 User Manual

Page 68: 1-2. indoor unit, 1-3. outdoor unit

Advertising
background image

64

10. CHECKING ELECTRICAL COMPONENTS

10-1. Measurement of Insulation

Resistance

The insulation is in good condition if the resistance

exceeds 2M

½

.

10-1-1. Power Supply Wires

Clamp the ground wire of the power supply wires with

the lead clip of the insulation resistance tester and

measure the resistance by placing a probe on either of

the power wires. (Fig. 1)

Then measure the resistance between the ground wire

and the other power wire. (Fig. 1)

10-1-2. Indoor Unit

Clamp an aluminum plate fin or copper tube with the

lead clip of the insulation resistance tester and mea-

sure the resistance by placing a probe on each termi-

nal screw on the terminal plate. (Fig. 2)

Note that the ground line terminal should be skipped

for the check.

10-1-3. Outdoor Unit

Clamp a metallic part of the unit with the lead clip of

the insulation resistance tester and measure the resis-

tance by placing a probe on each terminal screw where

power supply lines are connected on the terminal plate.

(Fig. 2)

10-1-4. Measurement of Insulation

Resistance for Electrical Parts

Disconnect the lead wires of the desired electric part

from terminal plate, capacitor, etc. Similarly disconnect

the connector. Then measure the insulation resistance.

(Figs. 3 and 4)

Refer to Electric Wiring Diagram.

If the probe cannot enter the poles because the hole is

too narrow then use a probe with a thinner pin.

NOTE

Insulation
tester

Probe

Clip

Ground wire

Terminal plate

Copper
tube or
metallic part

Clip

Insulation
tester

Probe

Copper
tube or
metallic part

Clip

Insulation
tester

Probe

Clip

Insulation
tester

Probe

Metallic
part

From fan motor,
compressor and
other parts

Fig. 1

Fig. 2

Fig. 3

Fig. 4

000-111

SM

(18-68)

00.3.17

11:49

AM

y [ W 64

Advertising
This manual is related to the following products: