B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS

12

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Step 4. Install field Wiring

CAUTION

Ground supply lead must be con-

nected to the wire attached to the

green ground screw located on the

outlet box. See

Figure 13

. failure to

do so will result in a potential safety

hazard. The appliance must be

electrically grounded in accordance

with local codes or, in the absence of

local codes, the National Electrical

Code, ANSI/NfPA 70-latest edition.

(In Canada, the current CSA C22-1

Canadian Electrical Code).

CAUTION: Label all wires prior to disconnec-

tion when servicing controls. Wiring errors

can cause improper and dangerous operation.

ATTENTION : Au moment de l'entretien

des commandes, étiquetez tous les fils

avant de les débrancher. Des erreurs

de cáblage peuvent entraîner un fonc-

tionnement inadéquat et dangereux.

Verify proper operation after installing.

A. All Models

• An optional unit-mounted ON/OFF switch

may be installed in the lower control com-

partment.

• An optional wall-mounted ON/OFF switch or

optional ON/OFF remote control kit also may

be used.

• If a wall-mounted ON/OFF control switch is

used, mount it in a convenient location on a

wall near the fireplace.

• If an optional Style View Door is used in

conjunction with an optional unit-mounted

ON/OFF switch, the switch may be mounted

onto the Style View Door per instructions

provided in kit.

• The gas valve is set in place and pre-wired at

the factory on all models.

Refer to Section B (below) for millivolt appli-

ances and Section C (below) for electronic

appliances.

B. Millivolt Wiring

(see Figure 12)

1. Read Section A, “All Models,” at left.
2. Wire the control switch within the millivolt

control circuit using the 15 feet of 2 conductor

wire supplied with the unit.

Note: The supplied 15 feet of 2 conductor

wire has one end of each conductor con-

nected to the gas valve circuit and the other

end of each conductor placed loose inside

the bottom compartment.

CAUTION: do Not connect the optional wall

switch to a 120V power supply.

C. Electronic Wiring

(see Figure 13)

Note: The electronic appliance must be con-

nected to the main power supply.
1. Read Section A, “All Models,” at left.
2. Route a 3-wire 120Vac 60Hz 1ph power

supply to the appliance junction box.

3. Remove the electrical inlet cover plate from

the side of the unit by removing the plate's

securing screws (see Figures 8-1 and 8-2

on Pages 9 and 10).

4. Remove the cover plate's knockout; then feed

the power supply wire through the knockout

opening and into the unit junction box.

5. Connect the black power supply wire to the

lower outlet's red pigtail lead and the white

power supply wire to the common terminal

of the outlet as shown in Figures 13 and 14.

6. Connect ground supply wire to pigtail lead

attached to outlet's green ground screw.

Note: Remote receiver should be located in the

wall, or if installed in the control compartment,

pulled all the way forward and completely to the

left or right against the corner posts. The glass

enclosure panel must be removed first to place

the receiver in the lower control compartment.
7. If using an optional control, wire it in the low

voltage circuit as shown in Figure 13.

Note: The supplied 15 feet of 2 conductor wire

has one end of each conductor connected

to the gas valve circuit and the other end

of each conductor placed loose inside the

bottom compartment.

8. After wiring is complete, replace cover plate.
Note: Do NOT install batteries in the battery

holder until needed (i.e., in the event of a

power outage or if operating the appliance

solely by batteries). The battery holder requires

two [2] "D" batteries.

3. Refer to Figure 11. The following venting

configurations may be installed:

Vertical Installations

Minimum overall height of the vent

system and appliance without an offset

must be 10 ft (2.54 m).

Offset Installations

Offset up to 45 degrees from vertical:

Minimum overall height of the vent

system and appliance must be 12 ft

(3.66 m). The lower part of the offset

may start at the fireplace flue collar.

Offset greater than 45 degrees and up

to 60 degrees from vertical: Minimum

overall height of the vent system and

appliance must be 15 ft (4.57 m). The

lower part of the offset may start at the

fireplace flue collar.

Maximum overall height of the vent system

and appliance should not exceed 40 ft

(12.19 m).

Install the B-vent system in accordance with

the vent manufacturer's instructions.

CAUTION: THIS APPLIANCE CANNOT BE

VENTEd HORIzONTALLY.

Note: Refer to the vent manufacturers instal-

lation instructions for variations of venting

techniques. If common venting of several units

is contemplated, it should be discussed with an

architect and the local Building Department.

do not place insulation materials within 1 in.

of the gas vent system.

Back View

Of Appliance

10 ft.

Minimum

Back View

Of Appliance

*12 ft. Min.

**15 ft. Min.

*with an offset up to 45 degrees

** with an offset greater than 45

degrees and up to 60 degrees

Vertical

Installations

Back View

Of Appliance

10 ft.

Minimum

Back View

Of Appliance

*12 ft. Min.

**15 ft. Min.

*with an offset up to 45 degrees

** with an offset greater than 45

degrees and up to 60 degrees

Offset

Installations

Figure 11