Cold climate insulation, Location – Superior SLBV-40PM User Manual

Page 5

Advertising
background image

SUPERIOR

®

B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS

COLd CLIMATE INSULATION

For cold climate installations, seal all cracks

around your appliance with noncombustible

material and wherever cold air could enter

the room. It is especially important to insulate

outside chase cavity between studs and under

floor on which appliance rests, if floor is above

ground level. Gas line holes and other openings

should be caulked or stuffed with unfaced

fiberglass insulation. Check local codes for

additional requirements.

If the fireplace is being installed on a cement

slab in cold climates, a sheet of plywood or

other raised, insulated platform can be placed

underneath to prevent cold transfer to the

fireplace and into the room. It also may help

to sheetrock the inside surfaces and/or tape

for maximum air tightness.

LOCATION

In selecting the location, the aesthetic and

functional use of the appliance are primary

concerns. However, vent system routing to

the exterior and access to the fuel supply are

also important.

Due to high temperatures, the appliance

should be located out of traffic and away from

furniture and draperies (Figure 3).

En raison des températures élevées,

l’appareil devrait être installé dans un

endroit où il y a peu de circulation et loin

du mobilier et des tentures (Figure 3).

The location should also be free of electrical,

plumbing or other heating/air conditioning

ducting.

These appliances are equipped with an inte-

gral combustion air door and actuator arm.

Combustion air kits are optional and must be

installed before removing the securing screw

allowing the movement of the combustion air

actuator arm (see Step 5 on Page 14).

Be aware that this is a heat-producing ap-

pliance. Objects placed above the unit are

exposed to elevated temperatures.

The appliance should be mounted on a fully

supported base extending the full width and

depth of the unit. The appliance may be located

on or near conventional construction materials.

However, if installed on combustible materials,

such as carpeting, vinyl tile, etc., a metal or

wood barrier covering the entire bottom surface

must be used.
These appliances may be used for bedroom

installations in the United States and are listed

accordingly. These units may not be installed

in bedrooms in Canada.

5

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 3: Typical Locations

Note: When the unit is installed with one side

flush with a wall, see Figure 5 on Page 7.