Fireplace and framing specifications – Superior SLBV-40PM User Manual

Page 9

Advertising
background image

SUPERIOR

®

B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS

fIREPLACE ANd fRAMING SPECIfICATIONS

NOTE: Diagrams, illustrations and

photographs are not to scale. Product

designs, materials, dimensions,

specifications, colors, and prices are

subject to change or discontinuance

without notice.

Input (BTU/HR) - MV & Electronic

Natural & Propane Gas

Models

Input Rate (BTU/hr)

SLBV-35N

17,000

SLBV-35P

17,000

SLBV-40N

22,000

SLBV-40P

20,000

Figure 8-1

framing dimensions

Model No.

A

B

C

SLBV-35

in.

35-1/4

35-1/4

16

mm

895

895

406

SLBV-40

in.

40-1/4

40-1/4

16

mm

1022

1022

406

“C” is the required framing depth dimension

when the finish material (drywall) thickness

is 1/2 in. (13mm).

fIREPLACE fRAMING SPECIfICATIONS

Construct framing with 2x4 or larger lumber.

A

B

C

A

1/2

Corner framing dimensions

Model No.

d

E

f

G

SLBV-35

in.

35-1/4

57-1/2

40-5/8

28-3/4

mm

895

1461

1032

730

SLBV-40

in.

40-1/4

61-13/16 48-11/32 30-11/16

mm

1022

1554

1101

779

9

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

F

Back wall of chase/enclosure

(including any finishing materials)

G

D

E

CORNER fRAMING dIMENSIONS

Advertising