B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS

Figure 17

Step 6. Connect the Gas Line

All codes require a shut-off valve mounted in

the supply line. The orientation of the shut-

off valve should face the front. Figure 16

illustrates two methods for connecting the gas

supply. A sediment trap is recommended in the

gas piping within the home to prevent moisture

and debris in the line from damaging the valve.

The flex-line method is acceptable in the U.S.A.

where local codes permit, however, Canadian

requirements vary depending on locality. Instal-

lation must be in compliance with local codes.

These appliances are equipped with a gas flex-

line for use in connecting the unit to the gas line.

See Figure 16 for flex-line description. The

flex-line is rated for both natural and propane

gas. A manual shut off valve is also provided

with the flex-line.

The gas control valve is located in the lower

control compartment.

Access the valve compartment by removing the

lower control compartment panel (see Figure

17) by lifting and pulling the panel forward.

The panel is mounted on supporting tabs at

the extreme right and left hand sides. Engage

the tabs into the reliefs in the panel.

The millivolt and electronic control valve has a

3/8" (10 mm) NPT thread inlet port.

Secure all joints tightly using appropriate

tools and sealing compounds (ensure propane

resistant compounds are used in propane ap-

plications). It is recommended to seal around

the gas line to prevent cold air leakage.

Gas line connection may be performed largely

outside of the confines of the control compart-

ment and without having to enter the firebox

behind the glass. Proceed as follows:

Acquire the shut-off valve and gas flex-line and

pull the assembly forward out of the compart-

ment. Separate the shut-off valve from the gas

flex-line. Determine the length of pipe needed

to route the gas line from the last fitting (shown

in Figure 9) to a point within the control com-

partment that will allow the shut-off valve to

be easily attached by hand to the gas flex-line.

Using pipe-dressing materials appropriate for

the gas type, securely affix the shut-off valve

to this determined pipe length at a convenient

location outside of the appliance lower control

compartment.
Refer to Figure 18. Insert the last length of gas

pipe with its attached shut-off valve into the

lower control compartment, and pass it through

the gas line access hole on the left side of the

appliance outer wrapper.
Using appropriate materials for the gas type,

thread the last length of pipe into the end of

the gas vent run and tighten in place using a

Length of pipe with attached

Gas Shut-Off Valve in Off position

(gas line CLOSEd)

Figure 18

Figure 16: Gas Connection

Gas

Valve

3/8" NPT x

Flare Fitting

3/8" Flex Tubing

3/8" Nipple

3/8" Union

3/8" Close

Nipple

3/8" Shut-off Valve

1/2" x 3/8"

Reducer

Gas

Stub

1/2" x 3/8" Flare

Shut-off Valve

Gas Solid Line Connector

Gas Flex Line Connector

*Sediment

Trap

3"

Min

Note: The gas supply

line must be installed in

accordance with building

codes by a qualified installer

approved and/or licensed

as required by the locality.

In the Commonwealth of

Massachusetts, installation

must be performed by a

licensed plumber or gas fitter.

Gas Flex Line

(Gas Shut-Off Valve is behind

door latch; see DETAIL, below)

Gas Control

Valve

Piezo

(Millivolt

units only)

Spring

Door Latch

(one of two)

Lower Control

Compartment

(shaded area)

Optional

Unit-Mounted

ON/OFF Switch

~

{

Note: Millivolt system shown. Electronic system controls are similarly located.

DETAIL:

Gas Shut-Off Valve

in ON position (gas line OPEN)

To shut OFF gas: Turn valve handle

perpendicular (cross-wise) to gas line.

pipe wrench external to the appliance between

the appliance outer wrapper and the framing.

Important: Turn the last piece of gas pipe in

the last fitting until the shut-off valve is posi-

tioned in a way that allows the shut-off valve

handle to be accessed in the lower control

compartment, easily operated throughout its

full range of motion.

Bring the flex-line to the shutoff valve by hand

and align the flare fittings. Tighten the fittings

by hand, and then use wrench to tighten com-

pletely, 1/4-turn at a time.