background image

Page 9-24

Section 9. Optional Accessories

SATO CL408e/CL412e Service Manual

PN 9001078

Rev. B

Flash Memory Expansion Installation

STEP

PROCEDURE

4.

Carefully press outward on the tabs on both ends of the Main PCB Board

Memory Frame to release the Standard Memory PCB. The Standard

Memory PCB should lift by itself when released. Remove the Memory

PCB from the frame. Note the indexing notches. Figs. 9-39

5.

Remove the Flash Memory Module from the anti-static bag handling the

module by the edges. Note the indexing notches. Insert the module into

the Main PCB Memory Frame at approximately 45

0

away from the Main

PCB Board. Gently push down to snap into position. Figs. 9-40

6.

Replace the cover reversing removal steps.

7.

Complete the Factory Reset Procedure.

NOTE: Many of the components on this board are susceptible to damage by static

electricity. To avoid damage, do not unpack new circuit boards from anti-static bags

until instructed to do so and use a wrist grounding strap.

STANDARD MEMORY PCB IN THE

MAIN PCB MEMORY FRAME

*

CAREFULLY PRESS OUTWARD

ON TABS ON BOTH ENDS OF THE

FRAME TO RELEASE THE MEMORY

PCB.

Figs. 9-39

INDEXING NOTCHES

*

*

PRESS OUTWARD

PRESS OUTWARD