Eye [x.xv] input [x.xv, Lcd panel — service mode – SATO CL 408e User Manual

Page 47

Advertising
background image

Page 2-27

Section 2. Configuration

SATO CL408e/CL412e Service Manual

PN 9001078
Rev. B

EYE

- When setting the "EYE" threshold, the voltage must be measured with nothing but

the label under the sensor and then again with the printed "eye" mark under the sensor.

The formula to be used for this is:
(High Voltage Level + Low Voltage Level) x 0.5 = Start Value

STEP

PROCEDURE

1.

Insert a label into the sensor and close the Label Hold-Down. Make

sure the printed "eye" mark in not under the sensor. Record the

voltage shown on the top line of the LCD panel. This line should have

the message "EYE" on the top line (DIP switch DSW2-2 = ON).

2.

Now pull the label forward until the "eye" mark is positioned under

the sensor (the voltage reading shown on the top line of LCD panel).

The voltage ranges measured should be within the following ranges:

Label Only = 0.3 - 0.5V

Eye-mark = Equal to or greater than 1.2V

above the low value.

If the measured values are outside this range, you may have trouble

finding a value that will work properly under all conditions. If this is

the case, a higher quality label may be needed to get adequate

performance.

3.

Calculate the starting point voltage using the formula.

4.

Use the LINE key to step the counter to the desired setting. The

display will increment one step for each time the LINE key is pressed.

If the LINE key is held down for more than two seconds, it will

automatically go into the fast scroll mode. The reading will advance

to a setting of 3.3 (the maximum voltage) after which it will

automatically wrap and start at "0.0" again. If a value of "0.0" is set,

the printer will automatically set the level each time the printer is

powered on with labels loaded or the head is closed.

5.

Once the setting is correct, pressing the FEED key will accept the

setting and advance to the Auto Online Feed display.

eye