SATO CL 408e User Manual

Page 83

Advertising
background image

Page 4-9

Section 4. Electric Checks and Adjustments

SATO CL408e/CL412e Service Manual

PN 9001078
Rev. B

4.5b Print Position Adjustment

Using the VR1 potentiometer on the main PCB board.

STEP

PROCEDURE

Refer to Section 4.2 for access to main PCB

1.Record all current dip switch positions, then place all switches in the OFF

position and the power switch OFF.

2.Turn VR1 on the main PC Board to the center position.
3.Place DSW2-4 in the ON (up) position.
4.Press the LINE and FEED key while simultaneously turning the power

switch ON.

5.When the printer beeps, release the keys.

The following screens will appear.

6.Place DSW2-4 in the OFF (down) position and the screen will display the

next screen.

7.Press the FEED key to display the next screen.

8.Confirm "None" then press the FEED key to display the next screen.

The default is Large.

9.Press the FEED key for a test print. Press the FEED key again to stop

printing.

10.Adjust the position using the VR1 potentiometer and feed another label.

When the adjustment is correct, turn the printer off. If the print position

can't be adjusted with the VR1, replace the Main PCB. Refer to Section 6.

initializing

rom v00.00.00.00

maintentance mode

dipsw2-4 on->Off

factory mode

counter clear

none

print size

small large

test print

press the feed key

VR1 adjustment range is
+/- 3.75mm.

Advertising
This manual is related to the following products: