Advanced mode, Counters mode, Counters hd dsp cut life – SATO CL 408e User Manual

Page 52: Lcd panel — counters mode

Advertising
background image

Page 2-32

Section 2. Configuration

SATO CL408e/CL412e Service Manual

PN 9001078

Rev. B

STEP

PROCEDURE

1.

Use the LINE key to step the underlined cursor to the desired counter,

the Head (HD) counter or the LIFE counter. The default position is

the Head Counter.

2.

Press the FEED key to display the current value (in meters) stored in

the counter.

3.

Press the FEED key to advance to the next screen.

LCD Panel — Counters Mode

STEP

PROCEDURE

1.

Press the LINE key while simultaneously turning the power on.

When the printer emits one long beep, release the LINE key to display

the first screen.

2.

Press the LINE key 3X to advance to the Counters Mode.

3

.

Press the FEED key to advance the display to the counters selections.

The Counters Mode is provided to allow the user to access the internal printer counters

and is entered from the Advanced Mode.

ADVANCED MODE

To Enter Advanced Mode:

counters mode

The counters are identified in the display as:

HD: Head Counter (should be reset when print head is replaced)

DSP: Dispense Counter

CUT: Cutter Counter

LIFE: Life Counter (cannot be reset)

Counters

hd dsp cut life

Counters
HD

DSP CUT LIFE

head counter

xxxxx m

head Count clear

Yes

no

Advertising
This manual is related to the following products: