45

Item

Lowest
Value

Highest
Value

Default
Value

Meaning

MNS

0.3 (mi)

0.8 (k)

2.0 (mi)

3.2 (k)

0.5 (mi)

0.8 (k)

Minimum Speed. Treadmill minimum operating speed in miles or kilometers,

based on current UNx setting.

MXS

5.0 (mi)

5.0 (k)

12.5 (mi)

20.0 (k)

5.0 (mi)

5.0 (k)

Maximum Speed. Treadmill maximum operating speed in miles or kilometers ,

based on current UNx setting.

ACC

25

60

25

Acceleration Time. Time in seconds to accelerate from current speed to a

specified higher speed.

DEC

20

60

20

Deceleration Time. Time in seconds to decelerate from current speed to a

specified lower speed.

AST

OFF

ON

OFF

Auto Stop Enable. Enables/disables Auto Stop function.

AFE

OFF

ON

ON

Auto Fan Enable. Enables/disables Auto Fan function.

PAU

30

120

60

Pause duration during a program, in seconds, either 30, 45, 60, 90 or 120.

MAINTENANCE MODE

Your Service Representative may need to check accumulated data about the past usage of your treadmill, test its display
controls, or investigate error messages. For these reasons, your treadmill is equipped with a Maintenance Mode. The

Maintenance Mode includes all of the items available through Manager Mode, plus additional items for Service and Diagnostic

use. To enter Maintenance Mode:

1. Press and hold the

,

and

keys together.

2. A beep will sound and “MAINTENANCE SETTINGS” will scroll once across the P

ROFILE

Window.

3. Release all keys. “SN” will display in the P

ROFILE

Window; the associated numeric value for the parameter will

display in the D

ISTANCE

Window.

NOTE:

The system will automatically exit MAINTENANCE SETTINGS if no key is pressed for 30 seconds.

The following keys are used to modify MANAGER SETTINGS:

Increase and Decrease Incline Keys:

Display the next (Increase) and previous (Decrease) parameters.

Keys will repeat if held.

Numeric Keypad:

Facilitates entry of the desired value for the displayed parameter. These keys do not save

the new value – see OK Key below.

OK Key:

Updates (saves) the value of the displayed parameter in Flash memory. “UPDATING” will scroll

once across the P

ROFILE

Window while the update is in process. When the update is complete, the P

ROFILE

Window will show the new value for the parameter.

NOTE:

To exit Maintenance Mode without saving any values or settings, press the S

TOP

key.

NOTE:

Unless otherwise specified, the

Item (parameter) name is shown in the P

ROFILE

Window, and the value of the

parameter is shown in the D

ISTANCE

Window.

The items that you may display and change with the previous keys are:

Item

Lowest

Value

Highest

Value

Default

Value

Meaning

SN

0

9999

N/A

Serial Number. S Series Treadmill serial number (set by factory).

DSW

1.0

99.99

N/A

Display Software. Display panel software version number (set by factory).
NOTE:

Software checksum value is displayed in C

ALORIES

Window; software

Build value is displayed in T

IME

Window

OHR

0

9999

0

Operating Hours. Total operating hours.

DST

0

9999

0

Distance. Total distance traveled in miles or kilometers, based on current UNx
setting.