Pc operation (continued), Response format in advanced operation – Sharp LC-M3700 User Manual

Page 44

Advertising
background image

43

US

PC Operation

<Response format in Advanced operation >

■ Normal response

1Response when no ID number has been set.

O

Carriage return code
(0D

H

, 0A

H

)

K

A response is returned when execution of the
pertinent command is finished.

2Response when an ID number has been set.

O

ID number of

responding monitor

Carriage return code
(0D

H

, 0A

H

)

K

SPC

0

0

1

Space (20

H

)

■ When a command has not been executed correctly*

1Response when no ID number has been set.

E

Carriage return code
(0D

H

, 0A

H

)

R

R

2Response when an ID number has been set.

E

Carriage return code
(0D

H

, 0A

H

)

R

R

SPC

0

0

1

ID number

Space (20

H

)

* This is returned when there is no such command, or when the command cannot be used in the

current state of the monitor (i.e. video auto-adjustment with video display).

* If communication has not been established for reasons like a bad connection with the monitor,

nothing is returned (not even ERR).

* If no monitor has been assigned the designated ID number (e.g. if the command IDSL0002[X] is

issued, but no monitor with ID=002 is found), ERR

XXX[X] is returned.

Continued on the next page.

PC Operation (Continued)

(ID number at the furthest end)

In the above case
IDSL0004

←Non-existent ID number

WAIT
ERR 003

←Monitor with ID=3 at the furthest end returns ERR

PC

Set 1

Set 2

Set 3

[Example]