Other control options

ID NUMBER

ID NO. SETTING

IDST

W

0 - 255

It sets the monitor's ID number.

R

0 - 255

It returns the monitor's ID number.

IDSL

W

1 - 255

Sets a monitor ID number. This ID number is only effective for the command
immediately after this command.

0

Clears the ID number if one has been designated.

IDLK

W

1 - 255

Sets a monitor ID number. This ID number is effective for the next and all
subsequent commands after this command.

0

Clears the ID number if one has been designated.

ID CHECK

IDCK

W

Displays selected ID number and the monitor's own ID number on the screen.

CONTROL LOCK

MENU DISPLAY

LMNU

WR

Normal (Menu Display is available)

1

1

Menu Display is not available.

REMOTE CONTROL

LREM

WR

Normal (Operational)

1

1

Disabled

CONTROL BUTTONS

LBTN

WR

Normal (Operational)

1

1

Disabled

POWER

LPOW

WR

Normal (Operational)

1

1

Disabled

RS232C

LCOM

WR

Normal (Operational)

1

1

Disabled

PIN

SET PIN

PSET

W

4 digits

Sets PIN (Activates lock function)

PSE+

W

4 digits

Sets PIN: for repeater control

INPUT PIN

PINP

W

4 digits

Input of set PIN (Temporary unlock)

PIN+

W

4 digits

Input of set PIN: for repeater control

CLEAR PIN

PCLR

W

4 digits

Initializes PIN

PCL+

W

4 digits

Initializes PIN: for repeater control

POWER-ON METHOD, ETC.

MAX VOLUME

MVOL

WR

1 - 60

1 - 60

Maximum volume limit. Only displays volume in numbers when set to other than 60.

FIX VOLUME

FVOL

WR

0

0

Off

1

1

Fixes volume at a constant value

OSD SETTING

ODSP

WR

0

0

Normal

1

1

No OSD is displayed.

DISPLAY BOOT

FINP

WR

0

0

Normal

OPTION

1

1

Starts with INPUT1 + [AV] input selection

2

2

Starts with INPUT1 + [Y/C] input selection

4

4

Starts with INPUT2. Returns ERR if INPUT2 selection is "Output"

5

5

Starts with INPUT3.

6

6

Starts with PC + [Analog] input selection

7

7

Starts with PC + [Digital] input selection

11

11

Starts with INPUT1 + [AV] input selection, and remains fixed

12

12

Starts with INPUT1 + [Y/C] input selection, and remains fixed

14

14

Starts with INPUT2, and remains fixed. Returns ERR if INPUT2 selection is "Output".

15

15

Starts with INPUT3, and remains fixed

16

16

Starts with PC + [Analog] input selection, and remains fixed

17

17

Starts with PC + [Digital] input selection, and remains fixed

SOUND INPUT SELECT

SNDS

WR

0

0

Normal

1

1

Uses INPUT1 audio as fixed source

2

2

Uses INPUT2 audio as fixed source

COVR

WR

0

0

Detached

1

1

Attached

PANEL PROTECTION COVER

ID NO. SETTING
(ONCE)

ID NO. SETTING
(SUBSEQUENT)

Maximum volume limit. Only displays volume in numbers when set to other than 60.