[Example: 4] Disabling remote control, monitor buttons and power operations (RS-232C daisy-chain

connection)

Note: Values returned by monitors are omitted because they vary depending on the number of

connected monitors.

PCL+xxxx

←(“xxxx” is the current PIN. “xxxx” is not necessary if no PIN is set.)

LREM001+

←Locks remote control

LBTN001+

←Locks monitor buttons

LPOW001+

←Locks power operation

PSE+xxxx

←(“xxxx” is new PIN.)

[Example: 5] Disabling remote control operation, operation using monitor buttons, and switching to the

power standby state using those controls for a specific monitor (example: ID=2) in a chain
of monitors connected via RS-232C.

Note: Response messages are omitted for convenience as the number of connected monitors

varies.

IDLK0002

←Select monitor with ID=2

PCLRxxxx

←(“xxxx” is the current PIN. “xxxx” is not necessary if no PIN is set.)

LREM0001

←Locks remote control

LBTN0001

←Locks monitor buttons

LPOW0001

←Locks power operation

PSETxxxx

←(“xxxx” is new PIN.)

IDLK0000

←Exit “IDLK” command

Settings and Adjustments (Continued)

If you forget your PIN

If you forget the PIN which you yourself set, perform the following operation when the PIN input screen

is displayed.

This allows you to temporarily unlock the function.

\

|

MENU

ENTER