8 led display – Siemens X-400 User Manual

Page 106

Advertising
background image

Installation and Commissioning

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches

106

C79000-G8976-C186-03

6.8 LED

Display

Overview

The following table shows the states indicated by the LEDs in the various display
modes. For more detailed information, refer to the subsections listed in the first col-
umn.

LED

Display

Mode A

Display

Mode B

Display

Mode C

Display

Mode D

F

Problem, signaling contact opens

L1

Power supply L1 is applied.

Power supply
L1 is moni-
tored

Power Module

(See 6.8.3)

L2

Power supply L2 is applied.

Power supply
L2 is moni-
tored

IN1/IN5 Signal at in-

put IN1

Signal at input
IN5

Signal at input
IN1

Signal at input
IN5

IN2/IN6 Signal at in-

put IN2

Signal at input
IN6

Signal at input
IN2

Signal at input
IN6

IN3/IN7 Signal at in-

put IN3

Signal at input
IN7

Signal at input
IN3

Signal at input
IN7

DI Module

(See 6.8.4)

IN4/IN8 Signal at in-

put IN4

Signal at input
IN8

Signal at input
IN4

Signal at input
IN8

RM

Device is operating as RM

STBY

Reserved (no function)

DM1

off on off on

Switch CPU

(See 6.8.5)

DM2

off off on on

P1

P2

P3

Ports

(See 6.8.6)

P4

Port status

Transmission
rate

Half / full du-
plex

Fault mask