System Description of SCALANCE X-400

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches

24

C79000-G8976-C186-03

2.2

Ports of SCALANCE X-400

SCALANCE X-400 provides you with electrical ports that can be used as gigabit
and ring ports. The expansion with media modules provides you with additional op-
tical ports. By using an extender module, you can increase the number of ports by
a maximum of eight ports.

2.2.1 10Base-T / 100Base-TX

Transmission Rate

The transmission rate of the electrical ports is 10 Mbps or as fast Ethernet ports
100 Mbps.

Transmission Mode

The transmission mode for 10Base-T / 100Base-TX is specified in the IEEE 802.3i
/ IEEE 802.3u standards of the Institute of Electrical and Electronic Engineers.

Autonegotiation (automatic detection of the best transmission modes) is standard.
The order in which they are selected is:

● 100Base-TX full duplex

● 100Base-TX half duplex

● 10Base-T full duplex

● 10Base-T half duplex

Two communication modes are possible:

● Half duplex mode

two-way alternate - it is only possible to either send or receive over the inter-
faces at any one time.

● Full duplex mode

two-way simultaneous - both communication partners can send and receive at
the same time.