Siemens X-400 User Manual

Page 136

Advertising
background image

Approvals, Certificates

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches

136

C79000-G8976-C186-03

!

Warning
In hazardous areas, personal injury or damage to property may occur if you make
or break an electrical circuit while a SCALANCE X-400 is in operation.
Do not connect or disconnect any live circuits unless risk of explosion can be exc-
luded with certainty.

FM Approval

The product complies with the requirements of the standards

● Factory Mutual Approval Standard Class Number 3611

● FM Hazardous (Classified) Location Electrical Equipment:

Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and
Non Incendive / Class I / Zone 2 / Group IIC / T4

ATEX Approval

The product complies with the requirements of the standard

● EN50021

!

Warning
Use under Zone 2 (or Div. 2) Ex-protection conditions requires the installation in a
housing. The housing has comply with class IP 54 according to standard EN
60529, in the scope of the EU directive 94/9 (Atex 100a).

Advertising